Eppendorf Vis Cuvettes

Eppendorf Vis Cuvettes
Eppendorf Vis Cuvettes
Eppendorf Vis Cuvettes
Eppendorf Vis Cuvettes

The Eppendorf Vis Cuvettes are disposable cuvettes made of clear plastic with a light transmission of 300 nm to 900 nm. These cuvettes are perfect for applications outside of the UV range, such as colorimetric protein assays (Bradford, Lowry, etc.), determining of the optical density of bacterial cultures (OD600 methods), and kinetic and fluorescence measurements. More information

Order Info

Product Information

The Eppendorf Vis Cuvettes are disposable cuvettes made of clear plastic with a light transmission of 300 nm to 900 nm. The Vis cuvettes are the perfect tool for applications outside of the UV range, for example, colorimetric protein assays (Bradford, Lowry, etc.), determining of the optical density of bacterial cultures (OD 600 methods), kinetic, and fluorescence measurements. Based on the volume you would like to measure, you can select semi-micro or macro cuvette.

Common photometric applications such as colorimetric protein assays (Bradford, Lowry, etc.), determining the optical density of bacterial cultures (OD 600) or kinetic measurements, often require a standard curve and many samples measurements. To support this high throughput, Vis Cuvettes are packaged in 10 boxes of 100 cuvettes each. The boxes enable safe storage of the cuvettes while offering convenient access to each cuvette. The Vis cuvettes can be used in all common photometers that accommodate 12.5 mm x 12.5 mm cuvettes.

Features

  • Two different cuvette sizes (semi-micro and macro) for a wide variety of volumes and applications
  • Disposable cuvettes made of clear plastic with a light transmission of 300 nm to 900 nm
 Macro Vis CuvetteSemi-micro Vis Cuvette
Colorimetric protein assaysyesyes
Cuvette blank--
Fluorescence measurementsyesyes
Height of light source8.5 mm – 15 mm8.5 mm – 15 mm
Light path height10 mm10 mm
Light transmission300 nm – 900 nm300 nm – 900 nm
Materialclear plasticclear plastic
Maximum filling volume4,500 µL3,000 µL
OD 600 methodsyesyes
Packing1,000 cuvettes (10 boxes × 100 cuvettes)1,000 cuvettes (10 boxes × 100 cuvettes)
Temperature controlyesno
Use in Eppendorf BioPhotometeryesyes
Use in Eppendorf BioSpectrometeryesyes
dsDNA concentration range--
Dimensions (W × D × H)12.5 × 12.5 × 45 mm12.5 × 12.5 × 45 mm
Minimum filling volume  
in Eppendorf photometers1,000 µL400 µL
in devices of other manufacturers2,500 µL1,500 µL

You might also consider