The epMotion 5073l is a flexible system for automating time-consuming and complex pipetting procedures with the epBlue™ software, making routine Liquid Handling tasks easier than ever. The pipetting procedure is more precise, reproducible and fully standardized, making your workplace more ergonomic and safer. The epMotion P5073 is a customized system for automatic PCR preparation in the 96 or 384 plate formats and is delivered with all accessories required for preparing PCR samples; only consumables need to be ordered separately.

Dispensing Tools


The epMotion workstations can automatically change the tools connected to its robotic arm.
Eight different dispensing tools are available and are based on Eppendorf classic air cushion pipetting technology

› Free-jet pipetting, no tubes, no wires, no air bubbles to minimize cross-contamination
› Contact pipetting, for better performance at volumes <1 μL
› Excellent pipetting precision, below 2% cv at 1 μL*
› Volume range: 0.2-10 µL, 1–50 μL, 20–300 μL and 40–1000 μL
› Single or 8-channel
› Autoclavable & easy to maintain
› Automatic calibration warning
› Calibration based on ISO 8655

*Eppendorf application note 168: »Evaluation of the Eppendorf epMotion® Pipetting Tools using the Artel MVS®

epMotion® 5073l

CleanCap - UV/HEPA


The CleanCap option can be configured for new epMotion 5073 & 5075 versions.
Here a UV light (254 nm) is used for decontamination and the HEPA filters
provide clean air inside of the epMotion.

epMotion® 5073l

Gripper

Tool


The gripper tool allows transport of labware on the worktable of epMotion 5073 or 5075 versions. It is loaded by automatic tool exchange and can be programmed easily in the software. The stacking of up to 5 plates is possible.

epMotion® 5073l

Features

  • 6 ANSI/SLAS microplate positions
  • Software assistants for simple, step-by-step application programming
  • Optical sensor1) for detecting liquids, labware, tips
  • Automatic replacement of 2 pipetting tools
  • Volume range of 1 to 1,000 μL for maximum pipetting accuracy
  • Compatible with tubes (0.2 to 50 mL) and microplates with up to 384 wells
  • Calibrated 1-channel and 8-channel pipetting tools
  • Optional UV lamp and HEPA filter system for decontamination and clean air conditions
  • Fully enclosed, compact housing with door lock
  • Option for compact EasyCon tablet or MultiCon PC controller by touch, mouse or keyboard, upgradable for barcode tracking and GLP/GMP software versions

1) US patent 6,819,437 B2

Applications

  • PCR set-up
  • Serial dilution and normalization of samples
  • Sample or reagent transfer
  • Sample mixing and tempering
  • Assay set-up
  • Media change and other cell culture applications
 epMotion® P5073epMotion® P5073cepMotion® 5073lepMotion® 5073lc
Gripper carrying capacity1,200 g1,200 g1,200 g1,200 g
Operationelectronicelectronicelectronicelectronic
Pipetting typeair-cushionair-cushionair-cushionair-cushion
Noise level~ 56 dB(A)~ 56 dB(A) HEPA off~ 56 dB(A)~ 56 dB(A)
Power supply100 – 240 V ±10 %, 50 – 60 Hz ±5 %100 – 240 V ±10 %, 50 – 60 Hz ±5 %100 – 240 V ±10 %, 50 – 60 Hz ±5 %100 – 240 V ±10 %, 50 – 60 Hz ±5 %
Max. power consumption600 W600 W600 W600 W
Dimensions (W × D × H)65 × 61 × 67 cm / 26 × 24 × 27 in65 × 61 × 77 cm / 26 × 24 × 27 in65 × 61 × 67 cm / 26 × 24 × 27 in65 × 61 × 67 cm / 26 × 24 × 27 in
Weight w/o accessories50 kg / 110.2 lb55 kg / 121.3 lb50 kg / 110.2 lb50 kg / 110.2 lb
X-Y-Z axis positioning accuracy    
Random deviation±0.3 mm±0.3 mm±0.3 mm±0.3 mm
Systematic deviation±0.1 mm±0.1 mm±0.1 mm±0.1 mm
Thermal module (optional)    
Cooling rate4 °C/min4 °C/min4 °C/min4 °C/min
Heating rate9 °C/min9 °C/min9 °C/min9 °C/min
Temperature range0 °C – 110 °C0 °C – 110 °C0 °C - 110 °C0 °C - 110 °C
Eppendorf EasyCon    
DisplayLCD color displayLCD color displayLCD color displayLCD color display
Display resolution1,024 × 600 pixels1,024 × 600 pixels1,024 × 600 pixels1,024 × 600 pixels
Interfaces4 × USB 2.04 × USB 2.04 × USB 2.04 × USB 2.0
Touch panelCapacitive touch panelCapacitive touch panelCapacitive touch panelCapacitive touch panel
Conductor – X, Y, Z Positioning    
Random measurement error±0.1 mm±0.1 mm±0.1 mm±0.1 mm
Detector    
Optical confocal infrared detectorContact-free recognition of fill level, inserted tools, labware, tip types and quantitiesContact-free recognition of fill level, inserted tools, labware, tip types and quantitiesContact-free recognition of fill level, inserted tools, labware, tip types and quantitiesContact-free recognition of fill level, inserted tools, labware, tip types and quantities
UV lamp    
Irradiation period per run15 min
Main wavelength254 nm (UV-C)
Radiation capacity after 100 h3,9 W
Radiation capacity at a distance of 1 m39 μW/cm2
HEPA filter    
Filter class according to EN 1822E 10
Volume flow70 – 80 m3/h
Dispensing tool    
Random measurement error (1 µL)1,2≤5 %≤5 %≤5 %≤5 %
Random measurement error (1,000 µL)1,2≤0.15 %≤0.15 %≤0.15 %≤0.15 %
Random measurement error (50 µL)1,2≤0.4 %≤0.4 %≤0.4 %≤0.4 %
Systematic measurement error (1 µL)1,2±15 %±15 %±15 %±15 %
Systematic measurement error (1,000 µL)1,2±0.7 %±0.7 %±0.7 %±0.7 %
Systematic measurement error (50 µL)1,2±1.2 %±1.2 %±1.2 %±1.2 %
1in pipetting mode, free jet, without pre-wetting, with distilled water, at 20 °C
2See Eppendorf Application Note 168 for typical pipetting performance