epMotion® 5070

epMotion® 5070
epMotion® 5070
epMotion® 5070
epMotion® 5070
epMotion® 5070
epMotion® 5070
epMotion® 5070

Order Info

Product Information

The epMotion 5070’s pipetting technology is based on the classic Eppendorf piston-stroke pipettes; thus, protocols previously carried out manually are easily transferred to epMotion 5070. Its compatibility to a wide range of predefined consumables also allows established procedures to be maintained. Before every run the optical sensor checks that the required labware is correctly positioned on the deck and it also checks tip type and quantity available.

Optical Sensor - Verify set-up before the Run


The optical sensor feature is included in all epMotion 5070, 5073 and 5075 systems. It checks the worktable loading for tips, differentiating between volume types and with or without filter. For partly filled epT.I.P.S. Motion boxes the optical sensor can count the available tips. The scanning feature is also useful to verify the labware type that was defined in the method by the user is at the right deck position before the run. The optical sensor even checks liquid volumes in vessels for safe operation.

epMotion® 5070

Dispensing Tools


The epMotion workstations can automatically change the tools connected to its robotic arm.
Eight different dispensing tools are available and are based on Eppendorf classic air cushion pipetting technology

› Free-jet pipetting, no tubes, no wires, no air bubbles to minimize cross-contamination
› Contact pipetting, for better performance at volumes <1 μL
› Excellent pipetting precision, below 2% cv at 1 μL*
› Volume range: 0.2-10 µL, 1–50 μL, 20–300 μL and 40–1000 μL
› Single or 8-channel
› Autoclavable & easy to maintain
› Automatic calibration warning
› Calibration based on ISO 8655

*Eppendorf application note 168: »Evaluation of the Eppendorf epMotion® Pipetting Tools using the Artel MVS®

epMotion® 5070

Ease of use and flexibility - EasyCon


The Eppendorf EasyCon tablet is optimized for simple and comfortable access to liquid handling automation. Its space saving size is designed especially for the smaller members
of the epMotion family, 5070 & 5073. It has a large color display and is operated by touch or mouse control. The key feature of the Eppendorf EasyCon tablet however is its flexibility with pre-installed software assistants for easy and fast application runs and the epBlue studio software for programming more complex liquid handling tasks.

› Touchscreen or mouse control
› Pre-installed software assistants
› epBlue software
› 4 × USB 2.0 ports for data transfer
› Data backup
› CSV and XML file exchange
› No extra mains/power supply device needed

epMotion® 5070

Features

  • 4 ANSI/SLAS worktable and 3 virtual positions
  • Maximum pipetting accuracy from 0.2 to 1,000 µL
  • Calibrated 1-channel and 8-channel pipetting tools
  • Optical sensor 1) for detecting liquids, labware, tips
  • Compatible with tubes (0.2 mL to 50 mL) and microplates with up to 384 wells
  • Automatic exchange of two pipetting tools
  • Optional software extensions for handling samples with barcodes or for integration to LIMS & ELN
  • Optional software extensions for integration to regulated process environments (GLP, GMP, 21 CFR)
  • Completely contained housing including door safety mechanism (except for 5070 CB, laminar-flow version)

1) Patent US 6,819,437 B2

Applications

  • Serial dilutions
  • Distributing reagents
  • Assay set-up
  • Sample transfer from individual tubes to plates
  • Reformatting plates
  • PCR set-up
  • Cell-based assay set-up
  • Immunoassay set-up
  • Setting concentrations or volumes
  • Media change
 epMotion® 5070
Operationelectronic
Pipetting typeair-cushion
SLAS/ANSI deck positions4
Power supply100 – 240 V ±10 %, 50 – 60 Hz ±5 %
Max. power consumption150 W
Dimensions (W × D × H)65 × 48 × 63 cm / 26 × 19 × 25 in
Weight w/o accessories45 kg / 99.2 lb
Conductor – X, Y, Z Positioning 
Random measurement error±0.1 mm
Systematic measurement error±0.3 mm
Detector 
Optical confocal infrared detectorContact-free recognition of fill level, inserted tools, labware, tip types and quantities
Dispensing tool 
Random measurement error (1 µL)1,2≤5 %
Random measurement error (1,000 µL)1,2≤0.15 %
Random measurement error (50 µL)1,2≤0.4 %
Systematic measurement error (1 µL)1,2±15 %
Systematic measurement error (1,000 µL)1,2±0.7 %
Systematic measurement error (50 µL)1,2±1.2 %
1in pipetting mode, free jet, without pre-wetting, with distilled water, at 20 °C
2See Eppendorf Application Note 168 for typical pipetting performance